Telemetry
The robot streams a TelemetryView at roughly the control-loop rate. Subscribe with the onTelemetry option; there is no polling accessor — telemetry is a stream, not a snapshot.
const teleop = new RemoteTeleop({
/* ...options as usual... */
onTelemetry: (t) => {
if (t.safety !== "ok") console.warn("robot stopped:", t.safety);
if (t.batteryPercent !== null && t.batteryPercent < 15) console.warn("low battery");
for (const [motor, fault] of Object.entries(t.motorFaults)) console.error(motor, fault);
},
});The fields
| Field | Type | Meaning |
|---|---|---|
loopHz | number | The daemon's measured control-loop rate. ~50 on a healthy robot. |
safety | SafetyState | "ok" / "safe_hold" / "latched". See the safety contract. |
watchdog | WatchdogState | "ok" / "warn" / "stop" — how your control stream is doing. |
tempC | number | The Pi's temperature, not a motor's. Motor heat surfaces via motorFaults and the over-temp latch. |
active | boolean | Whether the control data channel is open — i.e. whether jog/commands go anywhere. Also delivered on its own via onControlActive. |
linkMode | "lan" | "wan" | null | The measured ICE path. null until the candidate pair resolves. This is what picks the watchdog profile — it isn't something you declare. |
state | Record<string, number> | The lerobot-native pose dict. See Joint state. |
currents | Record<string, number> | Per-motor current. Raw units — see Currents. |
videoNet | VideoNetState | null | The adaptive-bitrate loop's link verdict. See Video. |
batteryPercent | number | null | Pack state-of-charge. See Battery. |
motorFaults | Record<string, string> | Per-motor hardware faults. See Motor faults. |
Joint state
state is the daemon's lerobot observation dict, carried verbatim so you can run forward kinematics off it:
"<motor>.pos"for every joint — arm joints normalized [-100, 100], grippers [0, 100]. These are not degrees. The units are declared in the handshake (robotInfo().normMode), so read them rather than assuming."x.vel"/"theta.vel"for the base."left_lift.pos"/"right_lift.pos"— rail height in real millimeters, zero at the pose the daemon started in.
The lift keys are omitted, not zeroed, when height is unknown
The rail tracker is startup-relative and can invalidate (dropped reads, an out-of-band move). When it does, the key disappears from the dict. Treat absence as "height unknown" — reading it as 0 puts a rail at the top of its travel in your model when it may be anywhere.
Currents
currents is per-motor Present_Current, keyed like "right_arm_gripper" (no .pos suffix). It's the "virtual tactile" signal — the same values that drive VR haptics and the on-screen grip-force readout.
These are raw Feetech LSBs, not milliamps
Convert with the exported helper rather than a magic number of your own:
import { currentMa, CURRENT_MA_PER_LSB, CURRENT_FULL_LSB } from "@nori/sdk";
const ma = currentMa(t.currents["right_arm_gripper"]); // LSB -> mACURRENT_FULL_LSB is the value that maps to a full grip-force bar. It's a display normalization mirroring the torque-limit span — not a current limit, and not a safety threshold.
The sign is meaningful (direction), so Math.abs() before you treat a reading as force.
Battery
batteryPercent is pack state-of-charge, 0–100, injected by the robot's bridge.
null means unknown, and there are several legitimate ways to get there: the robot has no battery monitor fitted, the monitor's reader is down, the pack voltage is out of range, or the robot is running an older bridge that doesn't send the field at all.
Render null as "—", never as 0%
A robot without a monitor is not a robot at 0% — rendering null as zero shows an empty battery on a fully charged robot.
Only percentage is reported today. Voltage, current, and time-remaining are not on the wire.
Motor faults
motorFaults maps a motor name to what's wrong with it. Only unhealthy motors appear — {} is the healthy steady state, and is also what an older daemon that doesn't send the field produces. Two distinct kinds of value live in it:
A decoded hardware fault, e.g. "overload,overheat (0x24)" — the servo's own status byte. The hex is authoritative; the decoded names are best-effort. Show the whole string; don't parse the names.
The exact string "no response" — the motor stopped answering the bus across several reads. It was dropped, unplugged, or lost power. This is a cabling fault, not a thermal one, and keeping it distinct is the point of the field: a dead motor used to be indistinguishable from a healthy one.
The same transitions also arrive as log lines (motor_fault / motor_unreadable / motor_recovered), so you can log edges rather than diffing the map yourself.
Diagnosing what you see: Safety states.